VMware vCenter Zero-Day: Patching Is Not Enough

A VMware vCenter zero-day, CVE-2026-123890 (CVSS 9.8), was patched on November 19, after Google’s Mandiant found a suspected China-linked group using it since early September. An attacker with network access gets an administrator session without a password, and the group used that to steal the keys that sign vCenter logins. Patching closes the flaw but cannot tell you whether someone is already inside.
What Happened With the VMware vCenter Zero-Day
Broadcom fixed the VMware vCenter zero-day on November 19 in advisory VMSA-2026-0009. It sits in the VMware Directory Service and lets an attacker with network access bypass authentication. According to Mandiant, a predictable value in the directory service’s remote-password exchange lets the attacker recover a session key and open a session as [email protected]. Broadcom lists no workaround, says Enhanced Linked Mode makes no difference, and calls it an emergency change. ESX hosts are not affected. Broadcom lists 8.0 U3m, 9.0.2.0200 and 9.1.1.0200 as the fixed vCenter builds, and 5.2.5 for VCF 5.x.
Mandiant attributes the attacks to Armory Castle (formerly UNC5221) and dates them to early September. The group came in through the BeyondTrust Remote Support zero-day we covered on October 20, moved to a Linux appliance without endpoint protection, scanned for VMware ports and ran a custom tool called BONESAW against vCenter. The tool copied the directory database, took the SAML signing key and created a new SSO administrator. A second tool then forged login tokens, which bypasses MFA. The attackers also switched on SSH through the appliance’s management interface, took vCenter’s master encryption key and database password, and reached ESX hosts, where they pulled Active Directory database files out of virtual machines. As of November 20, Broadcom’s advisory (revised that day) does not mention exploitation. As of November 20, the BSI page we checked shows no warning for this flaw.
Why It Matters
vCenter controls the virtual machines beneath it and often the logins that reach them. Whoever holds the SAML signing key can create administrator sessions that look legitimate and pass MFA, and that key does not change when you patch. The attackers also took the master key and the database password, so a patched vCenter can still be a compromised one. Mandiant adds that BONESAW’s build date is mid-July (a date that can be altered) and that it was probably written for wider use than this one intrusion.
vSphere 7.0 is the harder case. Mandiant says BONESAW works against 7.x and 8.x. Broadcom’s advisory does not list 7.0, which left general support on October 2, 2025, and tells customers to presume it is affected; SecurityWeek reports no public patch. We covered the same family before: the vCenter CVE-2026-59310 attacks in August and the BeyondTrust zero-day that started this chain.
What You Should Do Now
- Patch vCenter as an emergency change: 8.0 U3m, 9.0.2.0200, 9.1.1.0200 or 5.2.5 on VCF 5.x (all per VMSA-2026-0009). The update is not eligible for vCenter Quick Patch. If you are mid-upgrade to VCF 9.1.1, read Broadcom’s note on the back-in-time restriction first.
- On vSphere 7.0, SecurityWeek reports no public patch as of November 20. Ask Broadcom support if you hold an extended support contract, and keep management access to a minimum until you can migrate.
- Lock down the management plane, following Mandiant’s advice (test first): allow vCenter ports 443, 5480, 22 and 2012 only from admin workstations and filter the appliance’s outbound traffic.
- Check for signs of intrusion before you treat the system as clean. Look for SSO or local administrator accounts nobody created, SSH switched on at the vCenter appliance outside a change window, unexpected SSH keys on ESX hosts and odd files in /tmp on Linux appliances. Mandiant publishes indicators. If you find anything, treat vCenter as compromised: rebuild it, then rotate the SSO signing certificate and the service, ESX and Active Directory credentials. The rotation list is our recommendation, not Mandiant’s or Broadcom’s wording.
DIESEC Perspective
Mandiant’s account points at a gap that is common in mid-sized environments, though we have no data on how common: the edge appliance gets patched, the management network stays flat, and the Linux appliances in between run without endpoint protection. Those appliances are where the group worked. Ask this week who can reach ports 443 and 5480 of your vCenter from the rest of the network, and whether anyone would notice a new administrator account.
Not sure whether your vCenter is patched and unused by anyone else in the meantime? Contact DIESEC for a rapid vCenter patch verification and management-plane exposure review.
Sources: Google Cloud (Mandiant and GTIG) | Broadcom VMSA-2026-0009 Q&A | SecurityWeek | BleepingComputer
Published: 2026-11-23 | Category: Vulnerabilities & Patches | ~5 min read